Oxygen saturation in patients during hemodialysis at different altitudes

Introduction Patients undergoing hemodialysis may develop hypoxemia during the procedure, and hypoxemia may become more intense if hemodialysis is performed in a high altitude environment. Objectives To assess variations in oxygen saturation in patients undergoing hemodialysis at different altitude...

Full description

Bibliographic Details
Authors: Rosales-Mendoza, Karina; Gonzalez-Polar, Jose; Sumen , Romina; Vizcarra Vizcarra, Christian; Hurtado-Aréstegui, Abdias
Format: Article
Status:Published version
Publication date:2021
Country:Perú
Institution:CMP
Repository:Acta Médica Peruana
Language:Spanish
OAI Identifier:oai:amp.cmp.org.pe:article/2146
Online Access:https://amp.cmp.org.pe/index.php/AMP/article/view/2146
Access Level:Open access
Keyword:Oximetría cutánea
hemodiálisis
altitud
Cutaneous oximetry
hemodialysis
Altitude
_version_ 1878411718589153281
author Rosales-Mendoza, Karina
author2 Gonzalez-Polar, Jose
Sumen , Romina
Vizcarra Vizcarra, Christian
Hurtado-Aréstegui, Abdias
author2_role author
author
author
author
author_browse Gonzalez-Polar, Jose
Hurtado-Aréstegui, Abdias
Rosales-Mendoza, Karina
Sumen , Romina
Vizcarra Vizcarra, Christian
author_facet Rosales-Mendoza, Karina
Gonzalez-Polar, Jose
Sumen , Romina
Vizcarra Vizcarra, Christian
Hurtado-Aréstegui, Abdias
author_role author
collection Acta Médica Peruana
description Introduction Patients undergoing hemodialysis may develop hypoxemia during the procedure, and hypoxemia may become more intense if hemodialysis is performed in a high altitude environment. Objectives To assess variations in oxygen saturation in patients undergoing hemodialysis at different altitude levels. Material and methods This is a prospective case series, where patients from hemodialysis programs in three cities were assessed. These places were at 101-, 2335-, and 3825- meters above sea level. Patients had their oxygen saturation measured in a semi-sitting position with a pulse oxymeter device. Measurements were taken before, during, and at the end of hemodialysis sessions. Results Sixty-five patients undergoing hemodialysis were included. They were from three cities at different altitude above sea level. Oxygen saturation significantly decreased as long as altitude increased (97,32 ± 1,10 vs. 94,75 ± 2,17 vs. 84,85 ± 5,86 p= 0,00). Oxygen saturation showed changes before, during, and at the end of hemodialysis procedures at different altitude. Ferritin levels were lower in high altitude patients compared with those at sea level and at moderate altitude (131,75 [106,04 – 157,45] vs. 493,38 [273,19 – 713,56] vs. 550,66 [329,75-771,57] p=0,01). Hemoglobin values were lower in patients from middle altitude levels (10,8 [10,12-11,47] vs 11,32 [10,79-11,85] vs 11,84 [11,54-12,14] p=0,03) Conclusions In patients undergoing chronic hemodialysis oxygen saturation is reduced as long as altitude increases, and significant variations were found during hemodialysis procedures.
eu_rights_str_mv openAccess
format article
id PE_7cc8fcdd95a7a2baa8a193404fbdedde
identifier_str_mv 10.35663/amp.2021.383.2146
institution CMP
instname_str Colegio Médico del Perú
language spa
network_acronym_str PE
network_name_str Perú
oai_identifier_str oai:amp.cmp.org.pe:article/2146
publishDate 2021
publishDateSort 2021
publisher Colegio Médico del Perú
publisherStr Colegio Médico del Perú
reponame_str Acta Médica Peruana
spelling Oxygen saturation in patients during hemodialysis at different altitudes Saturación de oxígeno en pacientes durante hemodiálisis a diferentes altitudes Rosales-Mendoza, Karina Gonzalez-Polar, Jose Sumen , Romina Vizcarra Vizcarra, Christian Hurtado-Aréstegui, Abdias Oximetría cutánea hemodiálisis altitud Cutaneous oximetry hemodialysis Altitude Introduction Patients undergoing hemodialysis may develop hypoxemia during the procedure, and hypoxemia may become more intense if hemodialysis is performed in a high altitude environment. Objectives To assess variations in oxygen saturation in patients undergoing hemodialysis at different altitude levels. Material and methods This is a prospective case series, where patients from hemodialysis programs in three cities were assessed. These places were at 101-, 2335-, and 3825- meters above sea level. Patients had their oxygen saturation measured in a semi-sitting position with a pulse oxymeter device. Measurements were taken before, during, and at the end of hemodialysis sessions. Results Sixty-five patients undergoing hemodialysis were included. They were from three cities at different altitude above sea level. Oxygen saturation significantly decreased as long as altitude increased (97,32 ± 1,10 vs. 94,75 ± 2,17 vs. 84,85 ± 5,86 p= 0,00). Oxygen saturation showed changes before, during, and at the end of hemodialysis procedures at different altitude. Ferritin levels were lower in high altitude patients compared with those at sea level and at moderate altitude (131,75 [106,04 – 157,45] vs. 493,38 [273,19 – 713,56] vs. 550,66 [329,75-771,57] p=0,01). Hemoglobin values were lower in patients from middle altitude levels (10,8 [10,12-11,47] vs 11,32 [10,79-11,85] vs 11,84 [11,54-12,14] p=0,03) Conclusions In patients undergoing chronic hemodialysis oxygen saturation is reduced as long as altitude increases, and significant variations were found during hemodialysis procedures. Introducción Los pacientes en hemodiálisis pueden presentar hipoxemia durante este procedimiento, la cual puede ser mayor si la hemodiálisis se realiza en ciudades de mayor altitud. Objetivos Evaluar las modificaciones de la saturación de oxígeno en pacientes con enfermedad renal crónica en estadio 5 en hemodiálisis a diferentes altitudes. Material y métodos Estudio descriptivo, prospectivo observacional, de pacientes con enfermedad renal crónica estadío 5 en programa de hemodiálisis, en tres ciudades localizadas a diferente altitud: 101, 2335 y 3,825 metros sobre el nivel del mar, en los que se evaluó la saturación de oxígeno en posición semisentada con pulsoxímetro: antes, durante y al finalizar el procedimiento de hemodiálisis. Resultados Se incluyeron 65 pacientes en hemodiálisis, de 3 ciudades de diferente altitud, con características similares, la saturación de oxígeno disminuyó significativamente a medida que aumentaba la altitud (97,3 ± 1,1 vs 94,8 ± 2,1 vs 84,8 ± 5,9 p=0,001), la saturación de oxígeno no mostró cambios antes, ni durante la hemodiálisis en las diferentes altitudes. Los niveles de ferritina fueron menores en pacientes de gran altitud comparado con los de nivel del mar (132 ± 57 vs 493 ± 492 p=0,001).  Conclusiones En pacientes en hemodiálisis la saturación de oxígeno disminuye a medida que incrementa la altitud y no se encontró disminución significativa durante la hemodiálisis. Colegio Médico del Perú https://amp.cmp.org.pe/index.php/AMP/article/view/2146 10.35663/amp.2021.383.2146
spellingShingle Oxygen saturation in patients during hemodialysis at different altitudes
Rosales-Mendoza, Karina
Oximetría cutánea
hemodiálisis
altitud
Cutaneous oximetry
hemodialysis
Altitude
status_str publishedVersion
title Oxygen saturation in patients during hemodialysis at different altitudes
title_full Oxygen saturation in patients during hemodialysis at different altitudes
title_fullStr Oxygen saturation in patients during hemodialysis at different altitudes
title_full_unstemmed Oxygen saturation in patients during hemodialysis at different altitudes
title_short Oxygen saturation in patients during hemodialysis at different altitudes
title_sort Oxygen saturation in patients during hemodialysis at different altitudes
topic Oximetría cutánea
hemodiálisis
altitud
Cutaneous oximetry
hemodialysis
Altitude
topic_facet Oximetría cutánea
hemodiálisis
altitud
Cutaneous oximetry
hemodialysis
Altitude
url https://amp.cmp.org.pe/index.php/AMP/article/view/2146