Towards the real-time measurement of Ultrasound Fields by combining Schlieren Tomography and Wavefront Sensing

Recent advances in ultrasound generation such as ultrasonic holography and acoustic tweezers require methods for the fast characterization of pressure fields. Typically, this can be achieved by using a hydrophone, but the measurement of the three-dimensional (3D) pressure distribution in a few cm re...

Full description

Bibliographic Details
Authors: Colom, Mateu; Ricci, Pietro; Duocastella, Martí
Format: Article
Status:Published version
Publication date:2023
Country:España
Institution:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
Repository:Recercat. Dipósit de la Recerca de Catalunya
OAI Identifier:oai:recercat.cat:2445/222059
Online Access:https://hdl.handle.net/2445/222059
Access Level:Open access
Keyword:Ultrasons
Temps real (Informàtica)
Ultrasonics
Real-time data processing
_version_ 1878739392311328769
author Colom, Mateu
author2 Ricci, Pietro
Duocastella, Martí
author2_role author
author
author_browse Colom, Mateu
Duocastella, Martí
Ricci, Pietro
author_facet Colom, Mateu
Ricci, Pietro
Duocastella, Martí
author_role author
collection Recercat. Dipósit de la Recerca de Catalunya
description Recent advances in ultrasound generation such as ultrasonic holography and acoustic tweezers require methods for the fast characterization of pressure fields. Typically, this can be achieved by using a hydrophone, but the measurement of the three-dimensional (3D) pressure distribution in a few cm region is extremely time-consuming, with typical times ranging from hours to even days. Alternatively, visual methods like Schlieren techniques offer a rapid assessment of the pressure field, but they remain largely qualitative. In this work, we combine Schlieren tomography with wavefront sensing to fill this void and quantitatively reconstruct 3D ultrasonic fields within seconds. Our method is based on the simultaneous acquisition of intensity images with a Schlieren setup and phase maps with a Wavefront Sensor. Because optical phase differences are related to changes in refractive index in the medium and, at the same time, to changes in pressure, we can convert phase values into pressure maps. By feeding this information into the Schlieren sinograms, we obtain quasi-real-time 3D pressure fields with sub-millimetric resolution. This new optical method is a significant step forward toward the real-time and precise characterization of ultrasound
eu_rights_str_mv openAccess
format article
id ES_c09cb5dddf4d3166b945ce4f24ef35ee
institution Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
instname_str Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
network_acronym_str ES
network_name_str España
oai_identifier_str oai:recercat.cat:2445/222059
publishDate 2023
publishDateSort 2023
reponame_str Recercat. Dipósit de la Recerca de Catalunya
spelling Towards the real-time measurement of Ultrasound Fields by combining Schlieren Tomography and Wavefront Sensing Colom, Mateu Ricci, Pietro Duocastella, Martí Ultrasons Temps real (Informàtica) Ultrasonics Real-time data processing Recent advances in ultrasound generation such as ultrasonic holography and acoustic tweezers require methods for the fast characterization of pressure fields. Typically, this can be achieved by using a hydrophone, but the measurement of the three-dimensional (3D) pressure distribution in a few cm region is extremely time-consuming, with typical times ranging from hours to even days. Alternatively, visual methods like Schlieren techniques offer a rapid assessment of the pressure field, but they remain largely qualitative. In this work, we combine Schlieren tomography with wavefront sensing to fill this void and quantitatively reconstruct 3D ultrasonic fields within seconds. Our method is based on the simultaneous acquisition of intensity images with a Schlieren setup and phase maps with a Wavefront Sensor. Because optical phase differences are related to changes in refractive index in the medium and, at the same time, to changes in pressure, we can convert phase values into pressure maps. By feeding this information into the Schlieren sinograms, we obtain quasi-real-time 3D pressure fields with sub-millimetric resolution. This new optical method is a significant step forward toward the real-time and precise characterization of ultrasound https://hdl.handle.net/2445/222059
spellingShingle Towards the real-time measurement of Ultrasound Fields by combining Schlieren Tomography and Wavefront Sensing
Colom, Mateu
Ultrasons
Temps real (Informàtica)
Ultrasonics
Real-time data processing
status_str publishedVersion
title Towards the real-time measurement of Ultrasound Fields by combining Schlieren Tomography and Wavefront Sensing
title_full Towards the real-time measurement of Ultrasound Fields by combining Schlieren Tomography and Wavefront Sensing
title_fullStr Towards the real-time measurement of Ultrasound Fields by combining Schlieren Tomography and Wavefront Sensing
title_full_unstemmed Towards the real-time measurement of Ultrasound Fields by combining Schlieren Tomography and Wavefront Sensing
title_short Towards the real-time measurement of Ultrasound Fields by combining Schlieren Tomography and Wavefront Sensing
title_sort Towards the real-time measurement of Ultrasound Fields by combining Schlieren Tomography and Wavefront Sensing
topic Ultrasons
Temps real (Informàtica)
Ultrasonics
Real-time data processing
topic_facet Ultrasons
Temps real (Informàtica)
Ultrasonics
Real-time data processing
url https://hdl.handle.net/2445/222059