Assessment of the potential and limitations of elemental mass spectrometry in life sciences for absolute quantification of biomolecules using generic standards

Inductively coupled plasma-mass spectrometry (ICP?MS) has been widely used in Life Sciences for the absolute quantification of biomolecules without specific standards, assuming the same response for generic compounds including complex biomolecules. However, contradictory results have been published...

Full description

Bibliographic Details
Authors: Cid-Barrio, Laura; Calderón Celis, Francisco; Costa-Fernández, José Manuel; Ruiz Encinar, Jorge
Format: Article
Publication date:2020
Country:España
Institution:Universidad de Cantabria (UC)
Repository:UCrea Repositorio Abierto de la Universidad de Cantabria
Language:English
OAI Identifier:oai:repositorio.unican.es:10902/39484
Online Access:https://hdl.handle.net/10902/39484
Access Level:Open access
Keyword:Calibration
Hydrophobicity
Monomers
Peptides and proteins
Sulfur
_version_ 1878732141775290368
author Cid-Barrio, Laura
author2 Calderón Celis, Francisco
Costa-Fernández, José Manuel
Ruiz Encinar, Jorge
author2_role author
author
author
author_browse Calderón Celis, Francisco
Cid-Barrio, Laura
Costa-Fernández, José Manuel
Ruiz Encinar, Jorge
author_facet Cid-Barrio, Laura
Calderón Celis, Francisco
Costa-Fernández, José Manuel
Ruiz Encinar, Jorge
author_role author
collection UCrea Repositorio Abierto de la Universidad de Cantabria
description Inductively coupled plasma-mass spectrometry (ICP?MS) has been widely used in Life Sciences for the absolute quantification of biomolecules without specific standards, assuming the same response for generic compounds including complex biomolecules. However, contradictory results have been published on this regard. We present the first critical statistical comparison of the ICP-MS response factors obtained for 14 different relevant S-containing biomolecules (three peptides, four proteins, one amino acid, two cofactors, three polyethylene glycol (PEG) derivatives, and sulfate standard), covering a wide range of hydrophobicities and molecular sizes. Two regular flow nebulizers and a total consumption nebulizer (TCN) were tested. ICP?MS response factors were determined though calibration curves, and isotope dilution analysis was used to normalize the results. No statistical differences have been found for low-molecular-weight biocompounds, PEGs, and nonhydrophobic peptides using any of the nebulizers tested. Interestingly, while statistical differences were still found negligible (96-104%) for the proteins and hydrophobic peptide using the TCN, significantly lower response factors (87-40%) were obtained using regular flow nebulizers. Such differential behavior seems to be related mostly to hydrophobicity and partially to the molecular weight. Findings were validated using IDA in intact and digested bovine serum albumin solutions using the TCN (98 and 100%, respectively) and the concentric nebulizer (73 and 97%, respectively). Additionally, in the case of a phosphoprotein, results were corroborated using the P trace in parallel to the S trace used along the manuscript. This work seems to suggest that ICP-MS operated with regular nebulizers can offer absolute quantification using generic standards for most biomolecules except proteins and hydrophobic peptides.
eu_rights_str_mv openAccess
format article
id ES_3d655d1a235a00a5a90805ee72ae1df0
institution Universidad de Cantabria (UC)
instname_str Universidad de Cantabria (UC)
language eng
network_acronym_str ES
network_name_str España
oai_identifier_str oai:repositorio.unican.es:10902/39484
publishDate 2020
publishDateSort 2020
publisher American Chemical Society
publisherStr American Chemical Society
reponame_str UCrea Repositorio Abierto de la Universidad de Cantabria
spelling Assessment of the potential and limitations of elemental mass spectrometry in life sciences for absolute quantification of biomolecules using generic standards Cid-Barrio, Laura Calderón Celis, Francisco Costa-Fernández, José Manuel Ruiz Encinar, Jorge Calibration Hydrophobicity Monomers Peptides and proteins Sulfur Inductively coupled plasma-mass spectrometry (ICP?MS) has been widely used in Life Sciences for the absolute quantification of biomolecules without specific standards, assuming the same response for generic compounds including complex biomolecules. However, contradictory results have been published on this regard. We present the first critical statistical comparison of the ICP-MS response factors obtained for 14 different relevant S-containing biomolecules (three peptides, four proteins, one amino acid, two cofactors, three polyethylene glycol (PEG) derivatives, and sulfate standard), covering a wide range of hydrophobicities and molecular sizes. Two regular flow nebulizers and a total consumption nebulizer (TCN) were tested. ICP?MS response factors were determined though calibration curves, and isotope dilution analysis was used to normalize the results. No statistical differences have been found for low-molecular-weight biocompounds, PEGs, and nonhydrophobic peptides using any of the nebulizers tested. Interestingly, while statistical differences were still found negligible (96-104%) for the proteins and hydrophobic peptide using the TCN, significantly lower response factors (87-40%) were obtained using regular flow nebulizers. Such differential behavior seems to be related mostly to hydrophobicity and partially to the molecular weight. Findings were validated using IDA in intact and digested bovine serum albumin solutions using the TCN (98 and 100%, respectively) and the concentric nebulizer (73 and 97%, respectively). Additionally, in the case of a phosphoprotein, results were corroborated using the P trace in parallel to the S trace used along the manuscript. This work seems to suggest that ICP-MS operated with regular nebulizers can offer absolute quantification using generic standards for most biomolecules except proteins and hydrophobic peptides. Financial support from FC-GRUPIN-ID/2018/000166 (Asturias Regional Government) and CTQ2016–79412-P and PID2019- 109698GBI00 (Ministry of Economy and Competitiveness, Spain) is gratefully acknowledged. Authors want to thank also Agilent for the technical support. LCB acknowledges the Ph.D. grant (FPU15/04989) Spanish Ministry of Education. American Chemical Society https://hdl.handle.net/10902/39484
spellingShingle Assessment of the potential and limitations of elemental mass spectrometry in life sciences for absolute quantification of biomolecules using generic standards
Cid-Barrio, Laura
Calibration
Hydrophobicity
Monomers
Peptides and proteins
Sulfur
title Assessment of the potential and limitations of elemental mass spectrometry in life sciences for absolute quantification of biomolecules using generic standards
title_full Assessment of the potential and limitations of elemental mass spectrometry in life sciences for absolute quantification of biomolecules using generic standards
title_fullStr Assessment of the potential and limitations of elemental mass spectrometry in life sciences for absolute quantification of biomolecules using generic standards
title_full_unstemmed Assessment of the potential and limitations of elemental mass spectrometry in life sciences for absolute quantification of biomolecules using generic standards
title_short Assessment of the potential and limitations of elemental mass spectrometry in life sciences for absolute quantification of biomolecules using generic standards
title_sort Assessment of the potential and limitations of elemental mass spectrometry in life sciences for absolute quantification of biomolecules using generic standards
topic Calibration
Hydrophobicity
Monomers
Peptides and proteins
Sulfur
topic_facet Calibration
Hydrophobicity
Monomers
Peptides and proteins
Sulfur
url https://hdl.handle.net/10902/39484