Lossy mode resonances generated in planar configuration for two-parameter sensing
This work shows a new sensor structure for simultaneous measurement of two parameters, temperature and refractive index. The optical configuration consists of incidence of light on the edge of a soda-lime coverslip fully coated with a CuO thin film and partially coated with a PDMS thick layer. This...
| Authors: | ; ; ; ; |
|---|---|
| Format: | Article |
| Status: | Accepted version |
| Publication date: | 2021 |
| Country: | España |
| Institution: | Universidad Pública de Navarra |
| Repository: | Academica-e. Repositorio Institucional de la Universidad Pública de Navarra |
| OAI Identifier: | oai:academica-e.unavarra.es:2454/53757 |
| Online Access: | https://hdl.handle.net/2454/53757 |
| Access Level: | Open access |
| Keyword: | Optical sensor Planar waveguide Lossy mode resonances Refractive index Temperature |
| _version_ | 1878729486435876864 |
|---|---|
| author | Fuentes Lorenzo, Omar |
| author2 | Corres Sanz, Jesús María Domínguez Rodríguez, Ismel Del Villar, Ignacio Matías Maestro, Ignacio |
| author2_role | author author author author |
| author_browse | Corres Sanz, Jesús María Del Villar, Ignacio Domínguez Rodríguez, Ismel Fuentes Lorenzo, Omar Matías Maestro, Ignacio |
| author_facet | Fuentes Lorenzo, Omar Corres Sanz, Jesús María Domínguez Rodríguez, Ismel Del Villar, Ignacio Matías Maestro, Ignacio |
| author_role | author |
| collection | Academica-e. Repositorio Institucional de la Universidad Pública de Navarra |
| description | This work shows a new sensor structure for simultaneous measurement of two parameters, temperature and refractive index. The optical configuration consists of incidence of light on the edge of a soda-lime coverslip fully coated with a CuO thin film and partially coated with a PDMS thick layer. This planar configuration permitted to generate two separated lossy mode resonances (LMRs): one centered at 600 nm and the other at 1000 nm. The second resonance is induced by the PDMS layer and it can be used to measure the temperature due to its high thermo-optic coefficient (the sensitivity is -1.75 nm/°C in the temperature range from 20 to 40 °C), whereas the first resonance is used for sensing refractive index with sensitivity of 1460 nm/RIU in the refractive index range from 1.3328 and 1.37. Finally, a calibration test was carried out using a calibrated oil series with refractive index ranging from 1.33 to 1.36. This work demonstrates the possibility of generating multiples resonances in a single structure as simple as a coverslip, which can be used as a multi-parameter interchangeable sensor, especially suitable for biological applications or the detection of heavy metals in water. |
| eu_rights_str_mv | openAccess |
| format | article |
| id | ES_08daf8bfb4484d00a68d33b9c2191cb3 |
| institution | Universidad Pública de Navarra |
| instname_str | Universidad Pública de Navarra |
| network_acronym_str | ES |
| network_name_str | España |
| oai_identifier_str | oai:academica-e.unavarra.es:2454/53757 |
| publishDate | 2021 |
| publishDateSort | 2021 |
| publisher | IEEE |
| publisherStr | IEEE |
| reponame_str | Academica-e. Repositorio Institucional de la Universidad Pública de Navarra |
| spelling | Lossy mode resonances generated in planar configuration for two-parameter sensing Fuentes Lorenzo, Omar Corres Sanz, Jesús María Domínguez Rodríguez, Ismel Del Villar, Ignacio Matías Maestro, Ignacio Optical sensor Planar waveguide Lossy mode resonances Refractive index Temperature This work shows a new sensor structure for simultaneous measurement of two parameters, temperature and refractive index. The optical configuration consists of incidence of light on the edge of a soda-lime coverslip fully coated with a CuO thin film and partially coated with a PDMS thick layer. This planar configuration permitted to generate two separated lossy mode resonances (LMRs): one centered at 600 nm and the other at 1000 nm. The second resonance is induced by the PDMS layer and it can be used to measure the temperature due to its high thermo-optic coefficient (the sensitivity is -1.75 nm/°C in the temperature range from 20 to 40 °C), whereas the first resonance is used for sensing refractive index with sensitivity of 1460 nm/RIU in the refractive index range from 1.3328 and 1.37. Finally, a calibration test was carried out using a calibrated oil series with refractive index ranging from 1.33 to 1.36. This work demonstrates the possibility of generating multiples resonances in a single structure as simple as a coverslip, which can be used as a multi-parameter interchangeable sensor, especially suitable for biological applications or the detection of heavy metals in water. This work was supported by Spanish Agencia Estatal de Investigación (AEI). Fondo Europeo de Desarrollo Regional (FEDER) TEC2016-79367-C2-2-R. IEEE https://hdl.handle.net/2454/53757 |
| spellingShingle | Lossy mode resonances generated in planar configuration for two-parameter sensing Fuentes Lorenzo, Omar Optical sensor Planar waveguide Lossy mode resonances Refractive index Temperature |
| status_str | acceptedVersion |
| title | Lossy mode resonances generated in planar configuration for two-parameter sensing |
| title_full | Lossy mode resonances generated in planar configuration for two-parameter sensing |
| title_fullStr | Lossy mode resonances generated in planar configuration for two-parameter sensing |
| title_full_unstemmed | Lossy mode resonances generated in planar configuration for two-parameter sensing |
| title_short | Lossy mode resonances generated in planar configuration for two-parameter sensing |
| title_sort | Lossy mode resonances generated in planar configuration for two-parameter sensing |
| topic | Optical sensor Planar waveguide Lossy mode resonances Refractive index Temperature |
| topic_facet | Optical sensor Planar waveguide Lossy mode resonances Refractive index Temperature |
| url | https://hdl.handle.net/2454/53757 |